MaxWatt 4500W Petrol Inverter Generator
MaxWatt 4500W Petrol Inverter Generator with Electric Start

Maxwatt digital inverter generators provide the best available portable power while also being easy to transport, having a low environmental impact, and being exceptionally quiet. The MaxWatt 4500W Petrol Inverter Generator comes with an Electric Start and has a Warranty of Two Years. Ideal as a 4500W backup power supply and could be said to be one of the Best Inverter Generator Australia.

In addition to the electrical output being able to power all sensitive electronic equipment, MaxWatt generators are a vital component of recreational activities such as caravanning and camping. They are also helpful for use in the home as a backup power supply.

Parallel Cable:

Power increases by a factor of two when connecting two Maxwatt inverter generators in parallel. This can be done without making any additional purchases, as both units already have the necessary components for parallel operation, including the connection cable.

Parallel cables are included with each individual MaxWatt Inverter Generator. The parallel cable can be utilised to connect the MX2000iS, MX2000iY, MX2500iS, MX3000iY, or the MX4000iS.

What can be expected with this inverter generator

Combining the benefits of pure sine wave inverter technology and digital inverter technology. Low Noise, Measuring 62 dB Economy Adjustment for a Low Idle A Smart Engine Control system that adjusts the engine speed to improve fuel efficiency. Its maximum output of 4500W, one of the highest in its category, enables it to power up various electrical equipment at once. There is no need to purchase a parallel box because the parallel connection wire is included.

MX4500IS-NEW-DESIGN-scaled
MaxWatt 4500W Petrol Inverter Generator with Electric Start

It has a handle that is both slip-resistant and ergonomically constructed. Wheels and a telescopic handle with a quick-release mechanism make transportation simple. A gasoline tank that holds 10 litres of fuel allows for a running time of 9 hours when operating at 50 per cent load and 6.5 hours at 100 per cent load, respectively. Pure sine wave technology provides secure power for sensitive equipment. It complies with the emission regulations set forth by the Australian EPA. There is no need to assemble the generator because you must plug it in and start using it. To protect your investment, MaxWatt provides a warranty that is valid for two years.

A little on safety

Considering the number of natural disasters occurring in Australia lately and the need for backup power. It’s appropriate to discuss the most important safety factors relating to this inverter generator.

Poisoning by CDs

Carbon monoxide is very hard to detect and is a carcinogen produced by internal combustion engines, and can potentially cause death. It does not have a smell, a taste, or a visual appearance. ONLY operate an engine outside of a building and well away from any air intakes.

Under NO circumstances should an internal combustion engine be operated inside an enclosed or semi-enclosed environment. This includes homes, basements, garages, sheds, crates, recreational vehicles, boats, and pick-up truck beds. Even if you run a fan or crack the windows, these enclosed areas can still accumulate toxic gases.

control panel of the best inverter generatorA shock from the Electric Current or Electrocution

The generator’s output has a dangerously high voltage, which can be fatal. DO NOT carry out operations in damp environments or situations. Check to see that the generator has good grounding. Only extension cords with an outside rating that are grounded and of the appropriate size should be used.

NEVER connect the generator to the electrical socket directly through the plug. Any connection to the electrical system of a building needs to have a transfer switch installed by a professional electrician to isolate the generator from the power supplied by the utility.
In that case, there is a risk that utility personnel could be killed by back-feed from the generator into the electricity grid.

Disconnect the engine starting battery (if the generator has one) BEFORE conducting any repair on the generator to avoid it from being started by accident. Before anything else, you need to disconnect the connection from the battery post labelled with a NEGATIVE, NEG, or (-). The cable should be reconnected very last.

The following procedures need to be carried out to activate the generator:

Ensure the switch labelled “LOW IDLE MODE” is set to “OFF.” Make that the “ON” position is selected on the FUEL switch.

Starting by Hand:

  1. Place the switch that controls the engine in the “ON” position.
  2. Put one hand on the generator to keep it from moving while you carefully drawback the handle (recoil starter) until you feel a slight resistance.
  3. Then rapidly pull the starter cord to start the engine. Place the cord carefully back into the machine.
  4. Never give the cord a chance to snap back on itself.

Setting up the generator

Planning the power load

Make sure that the generator’s rated capacity is not exceeded by the load you put on it. Follow the instructions on page 18 to determine the starting and operating wattage needs for the electronic devices to which you will be providing power.

Proceeding to set up a mobile power source – the inverter generator.

The electrical power that this generator is capable of producing can reach its rated peak output (measured in watts). When the generator is being used as a portable power source, you can connect various electric gadgets and appliances to the generator’s electrical outlets to power them. This generator features two socket outlets that have an IP66 rated and are approved by the SAA.

Make sure that each electrical equipment or appliance is plugged into the correct outlet on the generator depending on the configuration of the device’s socket and its voltage and amperage rating. Under NO circumstances should the amperage rating of an outlet be exceeded.

Putting the generator to use as a backup for the building

To have the generator function as a backup for the building. You will need a qualified electrician to link it to the electrical system of the building through the installation of a transfer switch that has been approved. It is required that the transfer switch be installed in a manner that is compliant. With both the building’s electrical code and the specifications provided by the power company.

side panel of the inverter generatorThe following are the functions performed by a transfer switch:

A. disconnects your generator from the power lines provided by your utility company and then securely connects the generator to the electrical system in your building.

B. Connects your building’s generator to a specific subset of the building’s circuits that are essential for meeting the power requirements of an emergency.

Whether you use your generator as a portable power source or a backup power source linked to a building, you absolutely CAN NOT overload the generator in either scenario. The generator and any electrical devices attached to it may sustain significant damage if overloaded.

Suppose your generator is going to be connected to the system of your building. In that case, it is required to always be isolated from the utility power grid using an approved transfer switch installed by a licenced electrician. This must follow all applicable building and electrical codes and the power company’s guidelines.

Extension leads

It is possible to provide power to devices situated some distance away from the generator by using extension cords. However, ensure you only use outdoor-, grounded and permitted extension cords in Australia. It is essential to position the generator in an accessible area and, whenever feasible, avoid using lengthy extension lines and the risk of those leads being damaged by foot or vehicle traffic.

Extension leads should be heavy-duty, with a minimum of 1mm of the appropriate current rating. No less than 1mm cross-section of the conductor. Extension leads should also incorporate an earthing conductor to ensure no voltage difference between the generator and the power of the item.

Operating environment

Using a generator inside can result in death in a matter of minutes. Only utilise a generator OUTSIDE and a safe distance away from any building doors, windows, or vents. Do not light up in the vicinity of the generator. Never operate machinery close to an open flame, heat, or flammable materials. If ignited, the gasoline vapours emitted by this generator may be highly flammable and explosive, and they have the potential to cause severe burns or even death. Even though the open flame is not in direct contact with the gasoline. There is still a risk of an explosion if it is close.

Inverter Generator side panel 2
Maxwatt Inverter Generator Side Panel

Do not operate the generator in damp or rainy conditions; doing so considerably increases the danger of receiving an electrical shock. Never touch the generator, electronic equipment, or any cord while standing in water, while barefoot, or when your hands or feet are wet. Always make sure that you are operating the generator on a solid, dry, and level surface. Whenever the generator is in use, there should be a distance of at least five feet between it and any nearby structures or other pieces of machinery. Do not permit anyone who is not adequately trained to use the generator, especially youngsters.

the preparation of an Inverter Generator

Because gasoline may expand while the vehicle is running, the fuel tank should not be overfilled. It is not necessary to fill the tank to the absolute top. To enhance safety, you should always ground the generator before using it (for more information, read the section titled “GROUND THE GENERATOR”).

Keep some room for the gasoline to expand. Before starting the engine, you should always check for any spilt fuel. Make sure that any component of the generator is the electrical device. Or the power cable that is broken, damaged, or malfunctioning is either repaired or replaced before you begin using the equipment. Only a competent service professional should perform maintenance and repairs. Do not use receptacles or cords that are damaged in any way, including having insulation that is broken or cracked. In highly conductive locations, such as those with metal decking or steelwork, use a ground fault circuit interrupter, often known as a GFCI. To maximise safety during these procedures, it is advised that you use extension cables that come equipped with in-line GFCIs.

Regulations governing the electrical system

Suppose you want to connect the generator to the electrical system of a building to use it as standby power. In that case, you are REQUIRED to get the assistance of a qualified electrician and set up a transfer switch. These connections have to be following the laws and regulations governing the electrical system in the area. Failure to comply can result in a back-feed, putting utility personnel at risk of severe injury or even death. Under no circumstances may the generator be altered in any way. Suppose you modify the equipment or use it for a purpose other than what it was meant for. In that case, you risk causing significant injury to yourself or other people and voiding the warranty on the machine.